• B&R
  • ABB
  • SANTERNO
  • COMAU
X20TB1E
X20 TERMINAL BLOCK, 16X, TEMP.SENSOR
15.99 15.99 USD
X20TB1F
X20 TERMINAL BLOCK, 16X
11.31 11.31 USD
X20TB32
X20 TERMINAL BLOCK 240 VAC, 12X
13.65 13.65 USD
X20TB52
X20 TERMINAL BLOCK SAFETY, 12X
9.17 9.17 USD
X20TB72
X20 TERMINAL BLOCK SAFETY, 12-PIN, 240 V
13.65 13.65 USD
X20ZF0000
X20 DUMMY MODULE (ZERO FUNCTION)
9.17 9.17 USD
X67AC0D00
X67 PLUG MALE M8 3PIN PIRCING
13.46 13.46 USD
X67AC0M08
X67 THREADED CAPS M8, 50 PIECES
27.80 27.8 USD
X67AC0P20
X67 PLUG FEMALE M8 4PIN PIRCING
14.24 14.24 USD
X67AC2A00
X67 PLUG MALE M12(A) 5PIN SCREW
14.04 14.040000000000001 USD
X67AC2X01
X67 PLUG MALE M12(B) 5PIN SHIELD SCREW
30.43 30.43 USD
X67AC9B03
X67 PROFIBUS DP TERMINATOR M12
20.09 20.09 USD
X67AI1323
The module is equipped with 4 inputs with 12-bit digital converter resolution. The range of the input signal is either 0 to 20 mA or 4 to 20 mA.
478.43 478.43 USD
X67AI4850
The module is a 4-channel analog input module. It is used to evaluate potentiometer displacement gauges.
558.04 558.04 USD
X67AM1323
The module is equipped with 2 inputs and 2 outputs with 12-bit digital converter resolution. The range of the input/output signal is 0 to 20 mA.
501.06 501.06 USD
X67BC6321
PROFIBUS DP is based on the physics of the RS485 interface. Data transfer is controlled using a hybrid bus access procedure: Active stations receive communication rights via a token passing procedure and can then access all stations on the network according to the master-slave principle. The maximum time of circulation for a token can be configured, which results in a defined cycle time.Access represents various services for the user for both cyclic and for acyclic data transfer.This bus controller makes it possible to connect X2X Link I/O nodes to PROFIBUS DP. It supports PROFIBUS DP with all of its options and other additional properties. In addition to the device, module and channel diagnostics provided in the PROFIBUS standard, it is also possible, for example, to switch to the slot diagnostics option in S7 format. X67 or other modules based on X2X Link can be connected to the bus controller. The configuration of the modular system is optimally supported by PROFIBUS DP.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).
496.38 496.38 USD
X67BC7321
The bus controller makes it possible to connect X2X Link I/O nodes to CAN I/O. CAN I/O is a transfer protocol based on standard CAN bus that is fully integrated in the B&R system.Up to 43 logic I/O modules can be connected to the bus controller. Up to 16 of them can be analog modules.With multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).
451.11 451.11 USD
X67BC8321-1
The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. Additional X2X Link I/O nodes (X67 modules or other modules based on X2X Link) can be connected using the integrated X2X Link connection. Mechanically, POWERLINK is connected via an IP67-rated standard D-coded M12 Ethernet connector.POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.
564.87 564.87 USD
X67CA0A41.0020
M12 SENSOR CABLE, 2 M
27.12 27.12 USD
X67CA0A41.0150
M12 SENSOR CABLE, 15 M
100.48 100.48 USD